Type RVVPS Shielded Twisted Pair Flexible Wire of Rated Voltage of 300/300V with Copper Core, PVC Insulation and PVC Sheath
Applications:
For connecting wiring of electric equipment, instruments and automatic devices with shielding requirements.
Standards:
Compliant with JB/T 8734.5—2016 and obtained CCC.
Product Characteristics:
Rated voltage: 300/300V.
Continuous operating temperature: ≤70℃ for standard products, 90℃ or 105℃ for customized products.
No. of Pairs × No. of Cores × Nominal Conductor Cross-sectional Area mm2 | Conductor Construction No./mm | Insulation Thickness mm | Max. Avg. Insulation Outer Diameter mm | Nominal Wire Diameter of Shielding mm | Sheath Thickness mm | Avg. Overall Diameter of Completed Cables mm | Max. Conductor Resistance at 20℃ ?/km | Min. Insulation Resistance at 70℃ M??km | ||
Min. | Max. | Copper | Tinned Copper | |||||||
2×2×0.12 | 7/0.15 | 0.4 | 1.5 | 0.15 | 0.8 | 5.1 | 8.2 | 167 | 172 | 0.016 |
2×2×0.2 | 12/0.15 | 0.4 | 1.6 | 0.15 | 0.8 | 5.5 | 8.9 | 97.8 | 101 | 0.013 |
2×2×0.3 | 16/0.15 | 0.5 | 2.0 | 0.15 | 0.8 | 6.3 | 10.2 | 73.4 | 75.5 | 0.014 |
2×2×0.4 | 23/0.15 | 0.5 | 2.1 | 0.15 | 0.8 | 6.5 | 10.6 | 51.1 | 52.6 | 0.012 |
2×2×0.5 | 16/0.20 | 0.5 | 2.3 | 0.15 | 0.9 | 7.3 | 11.7 | 41.4 | 42.5 | 0.012 |
2×2×0.75 | 24/0.20 | 0.5 | 2.4 | 0.15 | 1.0 | 8.0 | 12.8 | 27.6 | 28.3 | 0.010 |
2×2×1.0 | 32/0.20 | 0.6 | 2.8 | 0.20 | 1.0 | 8.9 | 14.2 | 20.7 | 21.2 | 0.011 |
2×2×1.5 | 48/0.20 | 0.6 | 3.1 | 0.20 | 1.0 | 9.6 | 15.4 | 14.1 | 14.5 | 0.0094 |
2×2×2.5 | 50/0.25 | 0.7 | 3.9 | 0.20 | 1.1 | 11.8 | 18.9 | 8.47 | 8.71 | 0.0086 |
Please contact us for details of more products.